             Real time qPCR Lepgen-96  | 
            ||
| 
             High performance  | 
        ||
| 
             Reliability/flexibility/ affordable/Easy to use  | 
        ||
| 
             Performance  | 
        ||
| 
             Model  | 
            
             Lepgen-96  | 
        |
| 
             Capacity  | 
            
             - 96x 0.2ml tubes (low profile and standard) -8 slides tube  | 
        |
| 
             Dynamic range  | 
            
             1~1010 Copies  | 
        |
| 
             Applied probe  | 
            
             1st channel: FAM/ SYBR-Green  | 
        |
| 
             2nd channel: HEX, JOE, VIC, TET  | 
        ||
| 
             3rd channel: ROX Texas -Red  | 
        ||
| 
             4th channel: CY5  | 
        ||
| 
             Test method  | 
            
             four-fold fluorescence detection  | 
        |
| 
             Thermal cycle temperature control  | 
            
             semiconductor thermoelectric module  | 
        |
| 
             Temperature Range  | 
            
             4.0°C - 99.0°C  | 
        |
| 
             Heating and cooling Rate  | 
            
             ≥1.5°C/sec  | 
        |
| 
             Thermal Accuracy  | 
            
             ≤0.5°C (at 90°C)  | 
        |
| 
             Thermal Uniformity  | 
            
             ≤0.5°C (at 90°C)  | 
        |
| 
             Hot cover temperature range  | 
            
             50°C - 108°C  | 
        |
| 
             Optical detection excitation wavelength  | 
            
             300-800nm  | 
        |
| 
             Detection wavelength  | 
            
             500-800nm  | 
        |
| 
             Fluorescence repeatability  | 
            
             CV≤ 3%  | 
        |
| 
             Fluorescent linearity  | 
            
             r≥0.99 coefficient of correlation  | 
        |
| 
             Software application  | 
            
             genotyping by qualitative, absolute quantitative, standard solution curve, relative quantitative and end point method  | 
        |
| 
             Scanning method  | 
            
             full plate, specified rank scanning  | 
        |
| 
             Data export format  | 
            
             Excel,CVS  | 
        |
| 
             Custom report form  | 
            
             support  | 
        |
| 
             The operating system  | 
            
             Window 7/8/8.1/10  | 
        |
| 
             Minimum computer configuration  | 
            
             Intel or AMD Dual-2.8GHz, more than 4G memory and 128GB  | 
        |
| 
             Power Supply  | 
            
             AC 220V~, 50Hz, <800VA  | 
        |
| 
             Communication Ports  | 
            
             RS232, USB  | 
        |
| 
             Size  | 
            
             490mmX355mmX284mm  | 
        |
| 
             Weight  | 
            
             20Kg  | 
        |

ADD:No.10, Nanjing Street, Development Zone, Yantai, Shandong, 265500, P.R.China.

TEL:+86-535-6398536

FAX:+86-535-6398506

Email:marketing@lepu-medical.com